Command: CO (Copy). The HSM must be offline or in the secure state.
Function: To copy the Password for an Authorising Officer to another Smartcard so that it can be used to set the HSM into the Authorised state.
Inputs: Smartcard PIN: 4 to 8 alphanumeric characters.
Outputs: Text messages:
· Insert Card for Component Set 1 or 2 and enter the PIN.
· Insert Card for Authorising Officer and enter the PIN.
· Copy complete.
Errors: Card not formatted – card not formatted
Not a LMK card – card formatted for HSM settings or licence card.
Smartcard error; command/return: 0003 – an invalid PIN was entered.
Invalid PIN; re-enter: - PIN is fewer than 4 or greater than 8 digits.
Card not blank – copy failed
Example:
Offline> CO <Return>
Insert Card for Component Set 1 or 2 and enter PIN: ***** <Return>
Insert Card for Authorising Officer and enter PIN: ***** <Return>
Copy complete.